Cart is empty.
Device Image and link | Main purpose | Communication Interface | Additional communication | Relays count | Digital Inputs count | Digital Inputs range | Analog Inputs count | Analog Inputs range | Differential mode for analog inputs | Temperature Inputs count | Temperature Inputs range | Additional supply output for sensors | Real Time Clock (RTC) |
Communication Protocol |
Notifications | NTP (Network Time Protocol) | Inputs can control digital outputs (relays) | Logging for I/O | User can write and upload custom script | SD Card support | Box-to-box - Sender Mode | Box-to-box - Receiver Mode | Auto-reboot channels count | Ingoing ICMP (PING) mode | Outgoing ICMP (PING) mode | Ingoing / Outgoing HTTP GET (PING) mode | Save relay states in EEPROM and load on boot | Hardware Timer function for relays (Pulses) | Weekly schedule events | Android App | iOs App | |
smartDEN IP-16R | ![]() ![]() |
Remote control of electrical appliances | Ethernet | ![]() |
16 | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
SNMP, HTTP XML/JSON API | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
1 | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
smartDEN IP-16R-MT | ![]() ![]() |
Remote control of electrical appliances | Ethernet | ![]() |
16 | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
ModBus TCP, HTTP XML/JSON API | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
1 | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
smartDEN IP-16R-MQ | ![]() ![]() |
Remote control of electrical appliances | Ethernet | ![]() |
16 | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
MQTT, HTTP XML/JSON API | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
1 | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
smartDEN IP-WatchDog | ![]() |
Monitoring and restartig of network devices |
Ethernet | ![]() |
16 | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
HTTP XML/JSON API | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
16 | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
smartDEN IP-32IN | ![]() |
Remote monitoring of sensors | Ethernet | ![]() |
![]() |
16 | 0-30VDC | 8 | 0-10VDC | ![]() |
8 | -55 to +155°C | 5VDC, 12...24VDC | ![]() |
SNMP, HTTP XML/JSON API | SNMP TRAPS, HTTP POST (PUSH) | ![]() |
(in combination with relay module, over the network) |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
smartDEN Logger | ![]() |
Logging of sensors on SD card | Ethernet | ![]() |
![]() |
16 | 0-30VDC | 8 | 0-10VDC | ![]() |
8 | -55 to +155°C | 5VDC, 12...24VDC | ![]() |
HTTP XML/JSON API | HTTP POST (PUSH) | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
smartDEN Notifier | ![]() |
Notify the user via emails and smartphone messages | Ethernet | ![]() |
![]() |
16 | 0-30VDC | 8 | 0-10VDC | ![]() |
8 | -55 to +155°C | 5VDC, 12...24VDC | ![]() |
MQTT, HTTP XML/JSON API | MQTT, HTTP POST (PUSH), EMAILS | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
smartDEN IP-Maxi | ![]() |
Combined I/O Relay Module | Ethernet | ![]() |
8 | 8 | 0-30VDC | 4 | 0-10VDC | ![]() |
4 | -55 to +155°C | 12...24VDC | ![]() |
SNMP, HTTP XML/JSON API | SNMP TRAPS | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
smartDEN IP-PLC | ![]() |
Standalone work with user defined script program | Ethernet | ![]() |
8 | 8 | 0-30VDC | 4 | 0-10VDC | ![]() |
4 | -55 to +155°C | 12...24VDC | ![]() |
HTTP XML/JSON API | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
smartDEN IP-Maxi-MQ | ![]() |
Combined I/O Relay Module | Ethernet | ![]() |
8 | 8 | 0-30VDC | 4 | 0-10VDC | ![]() |
4 | -55 to +155°C | 12...24VDC | ![]() |
MQTT, HTTP XML/JSON API | MQTT | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
smartDEN IP-Maxi-MT | ![]() |
Combined I/O Relay Module | Ethernet | ![]() |
8 | 8 | 0-30VDC | 4 | 0-10VDC | ![]() |
4 | -55 to +155°C | 12...24VDC | ![]() |
Modbus TCP, HTTP XML/JSON API | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
smartDEN Opener | ![]() |
Controller for garrage doors, barriers, awnings, windows, roofs | Wi-Fi 802.11 b/g/n | RF 433 MHZ - via remotes | 5 (3 for motor control, 2 general purpose) | 3 | 0-30VDC | 1 | 0-5VDC | ![]() |
1 | -55 to +125°C | 5VDC, 12...24VDC | ![]() |
MQTT, HTTP XML/JSON API | MQTT, EMAILS | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |