Date: 2018-06-11
From 11 June 2018 all DAEnetIP4 devices will be shipped with firmware version v1.24. The most important updates:
1. Added digital filter for the analog inputs:
- The filter constant is 0 to 30 seconds;
- For the given timefreame they are collected 8 measurements;
- The average mesurement of the ADC is equal to the average sum of all the mesaurements after removal of the min and max values from the buffer;
- It can be set in General Settings or via SNMP OID .1.3.6.1.4.1.42505.1.3.7
2. Added non-reaction time for the analog inputs after toggling output (protection time):
- It is set in milliseconds (from 0 to 9999) - when 0 it is forbidden;
- It cab ne set in General Settings (paremeter Digital Outputs Filter) or via SNMP OID .1.3.6.1.4.1.42505.1.3.8
- For every outputit can be set or activated separately this protection time (in Digital Outputs Settings->Use Filter, SNMP OID .1.3.6.1.4.1.42505.1.2.3.1.14.х)
3. Added 8 new controlling modes for digital input -> digital output (two via level and six via edge):
- They can be set in Digital Outputs Settings->DI Mode or via SNMP OID .1.3.6.1.4.1.42505.1.2.3.1.12.х
4. Added second (differencial) analog input for controlling output:
- The first analog input in Digital Outputs Settings is renamed to "AI+ No", the second is named "AI- No".
- The second analog input can be set via SNMP SNMP OID .1.3.6.1.4.1.42505.1.2.3.1.13.х
5. The output control via XML/JSON/SNMP can be done now with 2 (TOGGLE) besides 0 (OFF) and 1 (ON);
7. In Digital Outputs page for DI No, AI+ No, AI- No they are used spinners instead of comboboxes for faster page loading;
8. In PWM page there are sliders;
9. In Monitoring and Control web page they are added buttons Toggle, color for output state and PWM control sliders;
10. Improved XML/JSON requests response time;